Detail Information |
|||
Category: | Diagnostic Medical Device | Description: | Ultrasound Assmbly |
---|---|---|---|
Service: | Repair Service For Ultrasound | Warranty: | 60 Days After Fixed |
Purpose: | Diagnosis Equiment For Clinic | ||
Highlight: | Clinic Ultrasound Machine Repair,GE Ultrasound Machine Repair |
Product Description
System | Faults | Solutions |
LOGIQ 500 | No image when scanning far field | Check power supply, reinsert the circuit board. Suggest to do metal earthing. |
LOGIQ 500PRO | Artifacts appear in color flow imaging (betweentimes) | Replace ACFP3 board |
LOGIQ 200E | No image on displayer, whereas normal image in workstation | Fix displayer |
LOGIQ 200E | Curved lines interpolated into sector-shaped image, from near field to far field | Replace DSC board, and make sure the system earthing |
LOGIQ 200 | No sound for the probe, requires multiple startup | Detect low voltage and external power supply (MST) |
LOGIQ BOOK | Lithium battery- short life | Replace lithium battery, and upgrade the system to 2349040-23 KB824146 |
LOGIQ BOOK | Crash | Reinstall the system |
LOGIQ 400MD | cardiac probe shows clutter filte, interference in far field | Repair cardiac probe S317, then test the voltage |
LOGIQ 400MD | Noisy in probe, no waves in scan area | Connecting board failure, try to connectwith TRDR and HBFR |
LOGIQ 400CL | Automatic interruption | High voltage failure, need repair |
LOGIQ 180 | Screen wobble | Displayer failure, need stabilized voltage supply |
LOGIQ 500MD | No image after boot (betweentimes) | Detect five low voltage value |
LOGIQ 200PRO | No image | Detect the channel board |
LOGIQ 9 | No scan area, no ultrasound image | MSTE and high voltage power supply failure, need repair |
Ultrasound parts that we can repair:
Repair List of Featured Ultrasonic Board & Assy | |||
Brand | System | Description | Part Number |
GE | Logiq P5 | CPU mainboard | 5168431 |
GE | Logiq P6 | CPU mainboard | |
GE | Logiq E9/vivid E9 | GFI2 | 5161631 |
GE | Voluson E6/Voluson E8 | RSR | KTI301394-2/KTI196357 |
GE | Voluson E6/Voluson E8 | RFI/ RFI21b Board | KTI300614/KTI302197-6 |
GE | Voluson S6/S8/P8 | BF64 | 5396937-2 |
GE | Voluson S6/S8/P8 | RFS board | 5364098-2/5364098-3 |
GE | Voluson S6/S10/P8 | BF192 board | 5357234 |
Aloka | Alpha 5 | mainboard | EP493700DD |
Aloka | Alpha 6 | RX Beam Former | EP555501AA |
Aloka | Alpha 6 | CW board | EP555700 |
Aloka | Alpha 6 | CPU mainboard | EP537000/EP563000 |
Aloka | Alpha 6 | TX/RX | EP555300 |
Aloka | Alpha 6/Alpha 7 | DOM | EP550000AA |
Aloka | Alpha 10 | RX Beamformer board | EP531800CE |
Aloka | Alpha 10 | wave generator Board | EP495000HH/EP495000HJ/EP495000FF |
Hitachi | F37 | TX/RS | EP557400/EP557300 |
Hitachi | F37 | mainboard | EP575700BC/EP560800 |
Aloka | F75 | USP board | EP556600 |
Aloka | F75 | Cell Board | EP558800 |
Hitachi | HI VISION Avius | RDBF board | 7513907A/7513612 |
Hitachi | Arietta 60 | CELL | EU-9160C |
Hitachi | Arietta 70 | TX | EP572300AA |
Hitachi | Arietta 70 | CELL | |
Hitachi | Noblus | CELL | |
Hitachi | Noblus | CONT-B | |
Hitachi | Ascendus | CELL | 7352830A |
Siemens | X150/G40 | BE | 10131804 |
Siemens | X300 | BE 2.0/BE 3.0/BE 7.5 | 10131990 |
Siemens | X700 | BE | 10136465 |
Siemens | X700 | RC | 10136467 |
Siemens | X700 | TI | 11014292 |
Siemens | Antares | BE | 7472421 |
Siemens | Antares | CB | 7288504 |
Siemens | S2000 | RM300 | 10852163 |
Siemens | S2000 high version/S3000 | RM301 | 10854749 |
iU22/iE33 | EMB excelsior motherboard | 453561419431/453561382231/453561419431 | |
iU22/iE33 | UMB Unified Motherboard | 453561254492/453561360251 | |
HD15 | ACB acquisition control board | 453561197145/453561197144 | |
HD15 | AIM board | 4.53561E+11 | |
CX50 | control panel | 4.53562E+11 | |
CX50 | mainboard | 453561368033/453561622163/453561495832 | |
Affiniti 70 | ACQ acquisition control board | ||
EPIQ 5/EPIQ 7 | ACQ Acquisition Module board | 453561734844/453561704246 | |
Biosound | Mylab Series | CPU mainboard | 9501361000 |
Toshiba | Aplio 300/400/500 | mainboard | PM30-38696 |
Toshiba | Aplio 500 | RX | ywm2056*a |
Toshiba | Xario 200 | TX | PM30-32732-1 |
Toshiba | Xario 200 | RX | PM30-32733-1 |
Remarks | |||
1.The repair cycle is within 3-5 days. | |||
2.Warranty after fixed:60 days. | |||
3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge. | |||
4.Package price is available if repair 3 pcs or more at one time. | |||
5.Extra discount for VIP partners. | |||
6.You could have different part No.under same description. |
FAQ
Q: How's the stock condition?
A: Wide variety of Ultrasound probe/board, over 10,000 pcs in stock, involved in popular brands and systems(GE, Hitachi Aloka, Siemens,Toshiba, , Biosound---)
Q: Is there any guarantee for the goods?
A: Fully-tested and safe packing before shipping, less than 3% warranty return claims of previous orders.
Q: Will you provide warranty?
A: Items are sold with NO WARRANTY, unless it is stated otherwise in the body of the proforma invoice/purchase order. Mostly 90 days for new original, 30/60 days for used.
Q: Can I have the goods returned if it is not working good?
A: Yes, goods are permitted to be returned in same received condition within 7 days. Refund will be handled within 2-4 working days after final confirmation (Freight & bank fee excluded). Shipping fee for return should be borne by buyers. No returns after 3 days if ordered wrong.
Q: If faults occurred after warranty date, can I contact you?
A: Sure, feel free to contact even years later. We'll look into the faults and try to find out some solutions/suggestions for you reference.
Q: How do exchange proceed?
A:The core/item for exchange must be complete and never repaired, and be sent to us after invoice approved.
Q: How about the payment terms?
A: All orders are 100% prepaid before delivery. We accept wire transferring / Western Union from bank, and cash. (US dollars, Euro, or CNY)
Q: How about delivery?
A: We ship worldwide. DHL/EMS/FedEx Express will be arranged within 1-5 working days after payment confirmed unless otherwise specified. We Seller are responsible for export Customs clearance in our end, and buyers for import Customs clearance in their end.
About Us
Rongtao Medical, one of the leading service companies in China, has sold over 10,000+ probes, 20,000+ medical parts and repaired 5,000+ machines in the worldwide from 2014. As a comprehensive medical device company, we provide a wide range of diagnostic ultrasound services and other associated items (endoscopy, patient Monitor and ventilator).
Following are the main projects we based on:
Repair Ultrasound (Ultrasonic board/ASSY repair, Ultrasound probe repair)
Repair Associated Items (Endoscopy repair, Patient monitor repair, Ventilator repair)
Parts & Accessories (Original/compatible clone ultrasound transducer, Ultrasound board/part, Ultrasonic biopsy needle guide, Patient monitor module)
How we support?
★ Professional & passionate pre-sale service team
★ 10 years experienced repair technician team
★ Reliable & responsible quality control team
★ Experienced & specialize after-sale technical support team
We are committed to using our expertise in the industry to identify and provide the right medical equipment to our customers at the best price in a timely and professional manner.
Our Vision -- To be the top preferred third-party service company worldwide!
Enter Your Message