Detail Information |
|||
Category: | Spare Part Medical | Description: | Imagic Digital |
---|---|---|---|
Warranty: | 60 Days/ 90 Days | Service: | Outright Sale |
Item: | Electronics Component | Condition: | Original |
Product Description
GE 4C-RS Curved Array Transducer
1. Type:convex
2. Frequency: 1.8 - 6.0 MHz
3. Compatible system: Vivid i Square/ Logiq e/ Vivid e
4. Application: Abdominal & OB/GYN
5. Condition: original, in good working condition
6. With 60 days warranty
Parts of GE probes we can offer:
Brand | Model | Compatible System |
GE | 3.5C | Logiq 3/ Logiq 5/ Logiq 7/ Logiq 9/ Logiq A5/ Logiq P5/ Logiq S6/Vivid7 |
GE | 3C | Logiq 3/ Logiq 5 |
GE | 3Cb | Logic 200 Pro |
GE | 3CRF | Logiq S6 |
GE | 3CRF-D | Logiq S8/ Logiq E9 |
GE | 3SP | LOGIQ P |
GE | 3Sp-D | Voluson E6/Voluson E8 / Bt08 & Higher version |
GE | 3S | vivid & Logiq series |
GE | 3S-RS | Loqigbook/XP/ Vivid-I |
GE | 3S-SC | venue 40 |
GE | 3S-RC | Logiq C5/ Logiq C2/ Logiq C3 |
GE | 3SC-RS | Vivid S5/ Vivid iq/ Vivid i |
GE | 3.8CA | Logiq P3 |
GE | 3V-D | Vivid E9 |
GE | 3.8C-RC | Loqig C2/Logiq C3/ Logiq C5/ Logiq premiums |
GE | 4C | Logiq & Vivid Series |
GE | 4C-RC | Logiq C2/Logiq C3/Logiq C5/Logiq Premium |
GE | 4C-RS | Vivid i Square/ Logiq e/ Vivid e |
GE | 4C-SC | Venue 40 |
GE | 4C-A | Voluson 730 |
GE | 4C-D | Voluson E6/ E8 and Vivid E9 |
GE | 4D3C-L | Logiq 9/ Logiq A5/ Logiq P5/ Logiq S6 |
GE | 4V-D | Vivid E9 |
GE | 4S | Logiq and Vivid series |
GE | 5S | pediatric cardiac |
GE | 5S-RS | Vivid q/ Vivid i/Vivid S5/Vivid S6 |
GE | 6.5C-RC | Vivid q/ Vivid i |
GE | 7L | Logiq and Vivid series |
GE | 7L-RC | Logiq C2/ C5/ Logiq Premium |
GE | 739L | Logiq 500 Pro/Vivid 3/Logiq 400 MD/Logiq 500 MD |
GE | 7S | Logiq9/ Logiq 7/ Logiq S6/ Logiq 5/ Logiq 3 /Vivid 7/Vivid 3 |
GE | 7.5L-RC | Logiq C2/Logiq C3/Logiq C5/Logiq Premium |
GE | 8C | Logiq & Vivid series |
GE | 8C-RS | Voluson i/ Voluson e/ Logiq i/ Logiqbook XP/ Logiqbook/ Vivid i (from rev. 6.1.0)/ Vivid S5 |
GE | 8L-RS | Logiq e/ Vivid e/ Vivid i and Logiq Book XP |
GE | 9L | Vivid 7 Pro/Vivid 3/Logiq 9/ Logiq 7/Logiq 5/Logiq 3/ Logiq 400 |
GE | 9L-D | Voluson E6/Voluson E8/Vivid E9 |
GE | 9L-RS | logiq e/ vivid e/ vivid I/ vivid q/ vivid s5/ vivid s6 |
GE | 10Lb-RS | Logiq book |
GE | 10S-RS | Logiq Book/ Logiq e/ Vivid e/ Vivid i/ Logiq i/ Vivid i Square |
GE | 10L | Logiq 3/5/7/9/ Vivid 3/4/A5/P5/7 Expert/7 Pro/ Logiq S6 |
GE | 11L | Logiq P5/A5/A5Pro/ Logiq P6/P6 Pro |
GE | 11L-D | premium GE ultrasound machines |
GE | 12L | Logiq & Vivid series |
GE | 12L-RS | Logiq e/ Logiq l/ Vivid e/Vivid I Voluson e/Voluson I/Vivid Q/Vivid S5/ Vivid S6 |
GE | 12L-SC | Venue 40 |
GE | 12S-D | Vivid E9 |
GE | AB2-7 | Voluson S6/ Voluson S8/Voluson 730 |
GE | AC2-5 | Voluson 730 |
GE | BE9C | Logiq series |
Knowledge Point:
Color-flow imaging
Color-flow imaging is an enhanced form of Doppler ultrasound technology. In a procedure similar to duplex ultrasound, it uses color to highlight the direction of blood flow. Vessels in which blood is flowing are colored red for flow in one direction and blue for flow in the other, with a color scale that reflects the speed of the flow.It can clearly understand the anatomical shape and activity of large blood vessels, and can visually display the direction, speed, range of blood flow, and whether there are blood flow disorders and abnormal pathways. The speed of blood flow determines the reflection frequency, which is represented by amplitude beam in spectral Doppler. The velocity of blood flow is fast, and the amplitude on the spectrum curve is high; the velocity of blood flow is slow, and the amplitude on the spectrum curve is low, so amplitude can accurately calculate the velocity of blood flow. Color Doppler images are displayed with different brilliance.
3D
In the ultrasonic detector, the detected 3D object image is displayed as a 3Ddisplay method by plane display. Three dimensional reconstruction refers to the use of ultra wide-band technology, on the basis of a large number of high-definition two-dimensional image accurate data provided, to make the collected image signal data characteristic and systematic, so as to form a 3Ddisplay. Its unique control signal function will make a series of 3Dimages fully displayed on the screen.