Detail Information |
|||
Category: | Ultrasound Machine For Veterinary | Description: | Ultrasound Instruments |
---|---|---|---|
Service: | Outright Repair Service | Warranty: | 60 Days |
Condition: | Original | Purpose: | Doppler Medical Device |
Highlight: | Mylab 20 Biosound Biosound Ultrasound,Veterinary Diagnostic Ultrasound System,Mylab 20 Diagnostic Ultrasound System |
Product Description
FAQ
How long does an ultrasound machine last usually?
Generally, transducers can last up to seven years with proper maintenance, storage, and transport. This will vary based on manufacturer recommendations.
Why do ultrasounds cost so much?
There are a lot of reasons why it's so expensive to see the doctor or stay in a hospital for any amount of time, including administrative costs, multiple treatments, drug costs, and the cost of equipment. Among that high-priced equipment is the ultrasound machines that doctors use to diagnose patients.
* DEMAND IS INCREASING
* ENGINEERING
* HARDWARE AND SOFTWARE
* ADVANCES IN TECHNOLOGY
Other Ultrasound Machine Maintenance we can offer:
Repair List of Featured Ultrasonic Board & Assy | |||
Brand | System | Description | Part Number |
GE | Logiq P5 | APS Power Supply | 5140505/5166108/5329667 |
GE | Logiq P5 | CPU mainboard | 5168431 |
GE | Logiq P5 | SYSCONPM | 5177848-3 |
GE | Logiq P6 | CPU mainboard | |
GE | Logiq P6 | PST Power Supply | 5245004/5244555 |
GE | Logiq P6 | SYSCONML | 5252326-3 |
GE | Logiq S7/Logiq S8 | CPS Power supply | 6626600 R02/5413249-3 |
GE | Logiq S7 | BF128 transmitting board | 5392446 |
GE | Logiq S7 | GFS board | 5371196 |
GE | Logiq S8 | BF192 Beamformer | 5357234-2 |
GE | Logiq S8 | GFS board | 5371196-2/5455247 |
GE | Logiq E9/vivid E9 | GTX | GA200726 |
GE | Logiq E9 | MRX Board | 5393908/5393912 |
GE | Logiq E9/vivid E9 | GFI2 | 5161631 |
GE | Logiq E9 | BEP Power Supply | 5393800-3/5166790-2 |
GE | Voluson E6/Voluson E8 | RSR | KTI301394-2/KTI196357 |
GE | Voluson E6/Voluson E8 | RST | KTI301148 |
GE | Voluson E6/E8/E10 | RSX | KTZ303054 /KTI303054 |
GE | Voluson E6/E8/E10 | RFM201 FE mainboard | KTZ303916 |
GE | Voluson E6/E8/E10 | RFM221 FE mainboard | KTZ303915 |
GE | Voluson E6/Voluson E8 | RFI/ RFI21b Board | KTI300614/KTI302197-6 |
GE | Voluson S6/S8/P8 | BF64 | 5396937-2 |
GE | Voluson S6/S8/P8 | BF128 | 5338209-2 |
GE | Voluson S6/S8/P8 | CPS Power supply | 5393431 |
GE | Voluson S6/S8/P8 | RFS board | 5364098-2/5364098-3 |
GE | Voluson S6/S10/P8 | BF192 board | 5357234 |
Aloka | Alpha 5 | mainboard | EP493700DD |
Aloka | Alpha 6 | RX Beam Former | EP555501AA |
Aloka | Alpha 6 | CW board | EP555700 |
Aloka | Alpha 6 | CPU mainboard | EP537000/EP563000 |
Aloka | Alpha 6 | TX/RX | EP555300 |
Aloka | Alpha 6/Alpha 7 | DOM | EP550000AA |
Aloka | Alpha 7 | RX Beam Former | EP539100BB/EP539500DG/EP539501DG |
Aloka | Alpha 7 | CPU mainboard | EP558900 |
Aloka | Alpha 7 | TI Board | EP539000 |
Aloka | Alpha 7 | TX board | EP548300BB |
Aloka | Alpha 7 | touch screen | L-Key-93H |
Aloka | Alpha 10 | RX Beamformer board | EP531800CE |
Aloka | Alpha 10 | wave generator Board | EP495000HH/EP495000HJ/EP495000FF |
Aloka | Alpha 10 | High-voltage Board | EP541800 |
Aloka | Alpha 10 | CPU mainboard | EP496000 |
Hitachi | F31 | RX Beamformer board | EP568900 |
Hitachi | F31 | mainboard | EP575700BC/EP560800 |
Hitachi | F37 | TX/RS | EP557400/EP557300 |
Hitachi | F37 | mainboard | EP575700BC/EP560800 |
Hitachi | F37 | BF Beamformer board | EP557400 |
Hitachi | F37 | RX mainboard | EP557500 |
Aloka | F75 | CONT-B | EP556700BB |
Aloka | F75 | USP board | EP556600 |
Aloka | F75 | Cell Board | EP558800 |
Hitachi | HI VISION Avius | RDBF board | 7513907A/7513612 |
Hitachi | HI VISION Avius | CONT-B | 7513734A |
Hitachi | HI VISION Avius/Preirus | Cell board | 7345930A |
Hitachi | HI VISION Preirus | RX Board | CZH4AA |
Hitachi | HI VISION Preirus | TX Board | 7513629A |
Hitachi | HI VISION Preirus | CONT-B | 7513640A/CZ84AJ |
Hitachi | Arietta 60 | TX | |
Hitachi | Arietta 60 | RX | |
Hitachi | Arietta 60 | CELL | EU-9160C |
Hitachi | Arietta 70 | TX | EP572300AA |
Hitachi | Arietta 70 | RX | EP572900/EP572200 |
Hitachi | Arietta 70 | CELL | |
Hitachi | Noblus | CELL | |
Hitachi | Noblus | CONT-B | |
Hitachi | Ascendus | TX | |
Hitachi | Ascendus | CELL | 7352830A |
Siemens | X150/G40 | BE | 10131804 |
Siemens | X300 | BE 2.0/BE 3.0/BE 7.5 | 10131990 |
Siemens | X700 | BE | 10136465 |
Siemens | X700 | RC | 10136467 |
Siemens | X700 | TI | 11014292 |
Siemens | Antares | BE | 7472421 |
Siemens | Antares | CB | 7288504 |
Siemens | S1000/S2000 | RM200 | 10038592 |
Siemens | S1000/S2000 | RM220 | 10853882/10439172 |
Siemens | S2000 | RM300 | 10852163 |
Siemens | S2000 high version/S3000 | RM301 | 10854749 |
iU22/iE33 | CB Channel Board | 453561156011/453561156012/453561303902 | |
iU22/iE33 | AIM Board | 453561210241/453561210243/453561210321/453561210243 | |
iU22/iE33 | FEC Front End Controller | 453561278261/453561278266/453561464291/453561153751 | |
iU22/iE33 | EMB excelsior motherboard | 453561419431/453561382231/453561419431 | |
iU22/iE33 | UMB Unified Motherboard | 453561254492/453561360251 | |
HD7/Envisor | T/R board | 453561448371 | |
HD11/HD11XE | SP Board | 453561210154/453561343282 | |
HD15 | ACB acquisition control board | 453561197145/453561197144 | |
HD15 | AIM board | 453561197306 | |
CX50 | control panel | 453561685791 | |
CX50 | mainboard | 453561368033/453561622163/453561495832 | |
CX50 | Power Supply board | 453561375144/453561384831/453561473243 | |
Affiniti 50 | ACQ acquisition control board | 4535161610416/4535161610426 | |
Affiniti 70 | ACQ acquisition control board | ||
EPIQ 5/EPIQ 7 | ACQ Acquisition Module board | 453561734844/453561704246 | |
Biosound | Mylab Series | CPU mainboard | 9501361000 |
Toshiba | Aplio 300/400/500 | mainboard | PM30-38696 |
Toshiba | Aplio 300/400/500 | VI | |
Toshiba | Aplio 300/400/500 | TX | PM30-38691 |
Toshiba | Aplio 500 | RX | ywm2056*a |
Toshiba | Xario 200 | TX | PM30-32732-1 |
Toshiba | Xario 200 | RX | PM30-32733-1 |
Remarks | |||
1.The repair cycle is within 3-5 days. | |||
2.Warranty after fixed:60 days. | |||
3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge. | |||
4.Package price is available if repair 3 pcs or more at one time. | |||
5.Extra discount for VIP partners. | |||
6.You could have different part No.under same description. |
Biosound/ Biosound Ultrasound System
|
Mylab 20, Mylab 30, Mylab 40, Mylab 50, Mylab 60, Mylab 70, Mylab 90, Mylab Twice, Mylab Class C, Mylab Five...
|
What information do customers need to offer in advance before repair?
1. The brand and model of the machine
2. Video or pictures of machine malfunction
3. Natural failure or artificial failure (for example, has it been repaired)
4. Accidental failure or frequent failure
5. All machines can do self-test, the same is true for HI VISION Avius and Preirus
6. Whether there is difference between connecting probe or not ( test selectively according to the machine fault, for example, if there is voltage error, the probe can be disconnected for test)
Enter Your Message