Detail Information |
|||
Condition: | Hitachi Original | Warranty: | 60/90 Days |
---|---|---|---|
Service: | Outright Sale, Exchange Sale | Category: | Medical Imaging Assmbly |
Description: | CONT Assy | Purpose: | Hospital Use |
Product Description
Hitachi Aloka CONT Assy for Prosound F75 (P/N: EP556700BB)
1. Model: EP556700BB
2. Full-tested, in excellent condition
3. We provide 60 days warranty and 2-4 days lead time
Note: We have most boards and assy for Prosound F75 device in stock
Other Hitachi ultrasonic board we can exchange/offer.
Brand | System | Description | Part number |
Aloka | Alpha 5 | mainboard | EP493700DD |
Aloka | Alpha 6 | RX Beam Former | EP555501AA |
Aloka | Alpha 6 | CW board | EP555700 |
Aloka | Alpha 6 | CPU mainboard | EP537000/EP563000 |
Aloka | Alpha 6 | TX/RX | EP555300 |
Aloka | Alpha 6/Alpha 7 | DOM | EP550000AA |
Aloka | Alpha 7 | RX Beam Former | EP539100BB/EP539500DG/EP539501DG |
Aloka | Alpha 7 | CPU mainboard | EP558900 |
Aloka | Alpha 7 | TI Board | EP539000 |
Aloka | Alpha 7 | TX board | EP548300BB |
Aloka | Alpha 7 | touch screen | L-Key-93H |
Aloka | Alpha 10 | RX Beamformer board | EP531800CE |
Aloka | Alpha 10 | wave generator Board | EP495000HH/EP495000HJ/EP495000FF |
Aloka | Alpha 10 | High-voltage Board | EP541800 |
Aloka | Alpha 10 | CPU mainboard | EP496000 |
Hitachi | F31 | RX Beamformer board | EP568900 |
Hitachi | F31 | mainboard | EP575700BC/EP560800 |
Hitachi | F37 | TX/RS | EP557400/EP557300 |
Hitachi | F37 | mainboard | EP575700BC/EP560800 |
Hitachi | F37 | BF Beamformer board | EP557400 |
Hitachi | F37 | RX mainboard | EP557500 |
Aloka | F75 | CONT-B | EP556700BB |
Aloka | F75 | USP board | EP556600 |
Aloka | F75 | Cell Board | EP558800 |
Hitachi | HI VISION Avius | RDBF board | 7513907A/7513612 |
Hitachi | HI VISION Avius | CONT-B | 7513734A |
Hitachi | HI VISION Avius/Preirus | Cell board | 7345930A |
Hitachi | HI VISION Preirus | RX Board | CZH4AA |
Hitachi | HI VISION Preirus | TX Board | 7513629A |
Hitachi | HI VISION Preirus | CONT-B | 7513640A/CZ84AJ |
Hitachi | Arietta 60 | TX | |
Hitachi | Arietta 60 | RX | |
Hitachi | Arietta 60 | CELL | EU-9160C |
Hitachi | Arietta 70 | TX | EP572300AA |
Hitachi | Arietta 70 | RX | EP572900/EP572200 |
Hitachi | Arietta 70 | CELL | |
Hitachi | Noblus | CELL | |
Hitachi | Noblus | CONT-B | |
Hitachi | Ascendus | TX | |
Hitachi | Ascendus | CELL | 7352830A |
Importance of maintaining ultrasound machine
Paying attention to preventive maintenance is the basic requirement of medical equipment engineers and technicians. Perform regular checks on equipment to ensure safe and effective operation of equipment, reduce downtime and save maintenance costs. Eliminate minor faults and avoid causing major faults to affect the normal operation of the hospital. Attention should be paid to any abnormality that occurs during the operation of the equipment. Sometimes a small abnormal phenomenon may be a precursor to a failure. If it is not checked, it may cause a greater failure and bring unnecessary losses to the hospital. Do not let the equipment work with faulty. Do not wait until the equipment is completely paralyzed before repairing. Routine maintenance can extend the service life of the equipment and improve economic efficiency.
Enter Your Message