Detail Information |
|||
Category: | Exchange CB Board | Description: | IU22 CB Board |
---|---|---|---|
Service: | Outright Sale, Exchange Sale | Warranty: | 60 Days/ 90 Days |
Condition: | Original | Purpose: | Diagnosis For Patient |
High Light: | IE33 Ultrasonic Board,2500 1741 06A Ultrasonic Board |
Product Description
Ultrasonic Board IU22/IE33 CB Board 2500-1741-06A/Medical Solutions
1. Part number: 2500-1741-06A
2. Compatible with iU22/iE33
3. in excellent working condition
4. with 60 days warranty
Outright/exchange/repair is available for ultrasound parts/Assy.
Other ultrasound parts that we can offer:
Repair List of Featured Ultrasonic Board & Assy | |||
Brand | System | Description | Part Number |
GE | Logiq P5 | APS Power Supply | 5140505/5166108/5329667 |
GE | Logiq P5 | CPU mainboard | 5168431 |
GE | Logiq P5 | SYSCONPM | 5177848-3 |
GE | Logiq P6 | CPU mainboard | |
GE | Logiq P6 | PST Power Supply | 5245004/5244555 |
GE | Logiq P6 | SYSCONML | 5252326-3 |
GE | Logiq S7/Logiq S8 | CPS Power supply | 6626600 R02/5413249-3 |
GE | Logiq S7 | BF128 transmitting board | 5392446 |
GE | Logiq S7 | GFS board | 5371196 |
GE | Logiq S8 | BF192 Beamformer | 5357234-2 |
GE | Logiq S8 | GFS board | 5371196-2/5455247 |
GE | Logiq E9/vivid E9 | GTX | GA200726 |
GE | Logiq E9 | MRX Board | 5393908/5393912 |
GE | Logiq E9/vivid E9 | GFI2 | 5161631 |
GE | Logiq E9 | BEP Power Supply | 5393800-3/5166790-2 |
GE | Voluson E6/Voluson E8 | RSR | KTI301394-2/KTI196357 |
GE | Voluson E6/Voluson E8 | RST | KTI301148 |
GE | Voluson E6/E8/E10 | RSX | KTZ303054 /KTI303054 |
GE | Voluson E6/E8/E10 | RFM201 FE mainboard | KTZ303916 |
GE | Voluson E6/E8/E10 | RFM221 FE mainboard | KTZ303915 |
GE | Voluson E6/Voluson E8 | RFI/ RFI21b Board | KTI300614/KTI302197-6 |
GE | Voluson S6/S8/P8 | BF64 | 5396937-2 |
GE | Voluson S6/S8/P8 | BF128 | 5338209-2 |
GE | Voluson S6/S8/P8 | CPS Power supply | 5393431 |
GE | Voluson S6/S8/P8 | RFS board | 5364098-2/5364098-3 |
GE | Voluson S6/S10/P8 | BF192 board | 5357234 |
Aloka | Alpha 5 | mainboard | EP493700DD |
Aloka | Alpha 6 | RX Beam Former | EP555501AA |
Aloka | Alpha 6 | CW board | EP555700 |
Aloka | Alpha 6 | CPU mainboard | EP537000/EP563000 |
Aloka | Alpha 6 | TX/RX | EP555300 |
Aloka | Alpha 6/Alpha 7 | DOM | EP550000AA |
Aloka | Alpha 7 | RX Beam Former | EP539100BB/EP539500DG/EP539501DG |
Aloka | Alpha 7 | CPU mainboard | EP558900 |
Aloka | Alpha 7 | TI Board | EP539000 |
Aloka | Alpha 7 | TX board | EP548300BB |
Aloka | Alpha 7 | touch screen | L-Key-93H |
Aloka | Alpha 10 | RX Beamformer board | EP531800CE |
Aloka | Alpha 10 | wave generator Board | EP495000HH/EP495000HJ/EP495000FF |
Aloka | Alpha 10 | High-voltage Board | EP541800 |
Aloka | Alpha 10 | CPU mainboard | EP496000 |
Hitachi | F31 | RX Beamformer board | EP568900 |
Hitachi | F31 | mainboard | EP575700BC/EP560800 |
Hitachi | F37 | TX/RS | EP557400/EP557300 |
Hitachi | F37 | mainboard | EP575700BC/EP560800 |
Hitachi | F37 | BF Beamformer board | EP557400 |
Hitachi | F37 | RX mainboard | EP557500 |
Aloka | F75 | CONT-B | EP556700BB |
Aloka | F75 | USP board | EP556600 |
Aloka | F75 | Cell Board | EP558800 |
Hitachi | HI VISION Avius | RDBF board | 7513907A/7513612 |
Hitachi | HI VISION Avius | CONT-B | 7513734A |
Hitachi | HI VISION Avius/Preirus | Cell board | 7345930A |
Hitachi | HI VISION Preirus | RX Board | CZH4AA |
Hitachi | HI VISION Preirus | TX Board | 7513629A |
Hitachi | HI VISION Preirus | CONT-B | 7513640A/CZ84AJ |
Hitachi | Arietta 60 | TX | |
Hitachi | Arietta 60 | RX | |
Hitachi | Arietta 60 | CELL | EU-9160C |
Hitachi | Arietta 70 | TX | EP572300AA |
Hitachi | Arietta 70 | RX | EP572900/EP572200 |
Hitachi | Arietta 70 | CELL | |
Hitachi | Noblus | CELL | |
Hitachi | Noblus | CONT-B | |
Hitachi | Ascendus | TX | |
Hitachi | Ascendus | CELL | 7352830A |
Siemens | X150/G40 | BE | 10131804 |
Siemens | X300 | BE 2.0/BE 3.0/BE 7.5 | 10131990 |
Siemens | X700 | BE | 10136465 |
Siemens | X700 | RC | 10136467 |
Siemens | X700 | TI | 11014292 |
Siemens | Antares | BE | 7472421 |
Siemens | Antares | CB | 7288504 |
Siemens | S1000/S2000 | RM200 | 10038592 |
Siemens | S1000/S2000 | RM220 | 10853882/10439172 |
Siemens | S2000 | RM300 | 10852163 |
Siemens | S2000 high version/S3000 | RM301 | 10854749 |
iU22/iE33 | CB Channel Board | 453561156011/453561156012/453561303902 | |
iU22/iE33 | AIM Board | 453561210241/453561210243/453561210321/453561210243 | |
iU22/iE33 | FEC Front End Controller | 453561278261/453561278266/453561464291/453561153751 | |
iU22/iE33 | EMB excelsior motherboard | 453561419431/453561382231/453561419431 | |
iU22/iE33 | UMB Unified Motherboard | 453561254492/453561360251 | |
HD7/Envisor | T/R board | 453561448371 | |
HD11/HD11XE | SP Board | 453561210154/453561343282 | |
HD15 | ACB acquisition control board | 453561197145/453561197144 | |
HD15 | AIM board | 453561197306 | |
CX50 | CX50 control panel | 453561685791 | |
CX50 | mainboard | 453561368033/453561622163/453561495832 | |
CX50 | Power Supply board | 453561375144/453561384831/453561473243 | |
Affiniti 50 | ACQ acquisition control board | 4535161610416/4535161610426 | |
Affiniti 70 | ACQ acquisition control board | ||
EPIQ 5/EPIQ 7 | ACQ Acquisition Module board | 453561734844/453561704246 | |
Biosound | Mylab Series | CPU mainboard | 9501361000 |
Toshiba | Aplio 300/400/500 | mainboard | PM30-38696 |
Toshiba | Aplio 300/400/500 | VI | |
Toshiba | Aplio 300/400/500 | TX | PM30-38691 |
Toshiba | Aplio 500 | RX | ywm2056*a |
Toshiba | Xario 200 | TX | PM30-32732-1 |
Toshiba | Xario 200 | RX | PM30-32733-1 |
Remarks | |||
1.The repair cycle is within 3-5 days. | |||
2.Warranty after fixed:60 days. | |||
3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge. | |||
4.Package price is available if repair 3 pcs or more at one time. | |||
5.Extra discount for VIP partners. | |||
6.You could have different part No.under same description. |
Knowledge point
3D image reconstruction
3D image reconstruction is a hot spot in ultrasound image processing and has become a development trend of ultrasound imaging. The first 3Dultrasound imaging commercial device uses mechanical scanning probes that oscillate in perpendicular directions to collect data of interest within 3 seconds, and perform image reconstruction to generate sagittal, coronal, and cross-sectional images. These planes can be adjusted within the range of ultrasound information capacity, and multiple continuous images can be seen.
There are many problems to be solved in 3Dultrasound imaging, including data acquisition methods, real-time image reconstruction, and clinical reference value. At present, four data collection methods have emerged: parallel scanning, rotating scanning, sector scanning, and free-hand Scanning. The most eye-catching 3Dultrasound imaging is real-time 3Dimaging. The key to real-time 3Dimaging is to use parallel data processing and shorten data acquisition time. Acoustic pulses are emitted in several directions at the same time, and simultaneously acquires and processes multiple sound beam information of the scan line, which obviously increases the complexity of the ultrasound imaging system.
Outright Sale /Exchange Advantages
1. Multiple choices (new/used/refurbished original, compatible/clone new)
2. wide variety of probes, over 1000 pcs in stock, involved in popular brands and systems(GE, Hitachi Aloka,,Siemens,Toshiba,Biosound---)
3. Convenient return and exchange process
4. Package price for bulk order (over 5 pcs)
5. Fully-tested and safe packing before shipping
6. Fast 1-5 days lead time
7. Experienced & specialize after-sale technical support team
8. New arrivals every 2-3 weeks
9. Less than 3% warranty return claims, earn good reputation
Enter Your Message