Detail Information |
|||
Category: | Medical Apparatus | Description: | G Cart Power Supply |
---|---|---|---|
Service: | Exchange Sale | Warranty: | 60 Days |
Condition: | Oringal | Purpose: | Imaging Scan System |
High Light: | IU22 IE33 Ultrasound Spare Parts,Power Supply Ultrasound Spare Parts,IE33 G Cart Power Supply |
Product Description
IU22 IE33 G Cart Power Supply Ultrasound Parts Accessories Healthcare Solutions Medical Equipment Supply
iU22 G Cart Power Supply Ultrasound Parts Accessories healthcare solutions
1. Available for Exchange Sale
2. Warranty: 60 days
3. Compatiable with iU22 iE33
Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range.
Other ultrasound parts related to that we can offer:
Brand | System | Description |
iU22/iE33 | Front End Controller 453561278261/453561278266/453561464291/453561153751 | |
iU22/iE33 | excelsior motherboard 453561419431/453561382231/453561419431 | |
iU22/iE33 | Unified Motherboard 453561254492 453561360251 | |
iE33 | G Cart Channel Board 453561303332 | |
iE33 | TI board 453561167791 | |
iE33 | Front End Controller board 453561278265 | |
iE33 | PC components | |
iE33/iU22 | version G Cart power boardMP6-3L-0M 73-560-7011 453561642151/453561395402/453561395432 | |
ClearVue350 | AC/DCpower board | |
ClearVue350 | numeric keyboard | |
ClearVue350 | track board | |
CX50/CX30 | AC power board adapter 453561367414 | |
CX50 | Channel board 453561662431 | |
CX50/CX30 | power board 453561375144 | |
CX50 | control panel 453561685791 | |
CX50 | monitor | |
CX50 | systems 3.1.1 | |
CX50 | TI board 453561473251 | |
CX50 | QWERY Alphanumeric Keyboard numeric keyboard 453561364341 | |
EPIQ 5 | ACQ Acquisition Module board 453561734844/ 453561704246 | |
EPIQ 5 | channel board 453561704244 version A | |
Affiniti 50G | mother board 453561736531B | |
Affiniti 50 | ACB Assy acquisition control board | |
Affiniti 70 | ACB Assy acquisition control board | |
ATL | HDI-3500/HDI-5000 | AIFOM ASSY 7500-1413-03A |
ATL | HDI-3500/HDI-5000 | Module Assy 3500-3079-01 |
ATL | HDI-3500/HDI-5000 | power board 2500-1342-02A |
ATL | HDI-3500/HDI-5000 | SPM 3500-2988 |
ATL | HDI-3500/HDI-5000 | PIM board 7500-1917-02c |
Knowledge Point
Color Doppler flow imaging
Color Doppler flow imaging system can simultaneously display B-type image and Doppler blood flow data (blood flow direction, flow velocity, flow dispersion) of dual ultrasound scanning system. Color power angio(CPA) detected the backscattered energy of blood cells in the blood flow, which did not distinguish the flow direction, and had nothing to do with the angle θ (the angle between the direction of sound wave and the direction of blood flow). CPA can improve the sensitivity of blood flow detection, especially suitable for displaying low-speed blood flow of small vessels, but can not show the direction of blood flow.
Common failures of color Doppler ultrasound
1. Control panel failure
2. System software, application software failure
3. Back end failure
4. Power failure (Main power supply, Low-voltage power supply, High-voltage power supply)
5. Transducer Probe failure
6. Front-end failure (Interface board, Transmitter, Receiver, Control, VIDEO, Front-end connection)
7. Display failure (Display, Workstation, Touch screen)
8. Failure caused by external environment
Front end troubleshooting summary
1. The front and back connection processing board has multiple functions
2. TR Board, image processing
3. Probe interface board failure
4. The back end board is responsible for the whole machine
5. The video board is responsible for image problems
Enter Your Message