logo
Send Message
Guangzhou Rongtao Medical Tech LTD.
Request A Quote
English

Toshiba SSA-770A Ultrasound Spare Parts AC DC Power Supply

Product Details:
Brand Name: Toshiba
Model Number: BSM31-2013E-6
Payment & Shipping Terms:
Price: Negotiable
Packaging Details: Neutral Package
Delivery Time: 2-4 work days
Payment Terms: T/T,Western Union
  • Detail Information
  • Product Description

Detail Information

Category: Ultrasound Medical Device Description: Healthcare Solutions
Service: Outright Sale Warranty: 60 Days/ 90 Days
Condition: Original Toshiba Purpose: Ultrasonography
Highlight:

SSA-770A Ultrasound Spare Parts

,

Toshiba Ultrasound Spare Parts

,

SSA-770A AC DC Power Supply

Product Description

Diagnosis System Toshiba SSA-770A AC/DC Power Supply Ultrasonic Parts
 
1. Compatible system: SSA-770A

2. in excellent working condition
3. with 60 days warranty

4. Modle: BSM31-2013E-6

 

 

Outright/exchange/repair is available for ultrasound parts/Assy.

 
 

 

 

Toshiba SSA-770A Ultrasound Spare Parts AC DC Power Supply 0

 

Toshiba SSA-770A Ultrasound Spare Parts AC DC Power Supply 1

 

 

Other ultrasound parts  that we can offer:

 

Repair List of Featured Ultrasonic Board & Assy
Brand System Description Part Number
GE Logiq S7/Logiq S8 CPS Power supply 6626600 R02/5413249-3
GE Logiq S7 BF128 transmitting board 5392446
GE Logiq S7 GFS board 5371196
GE Logiq S8 BF192 Beamformer 5357234-2
GE Logiq S8 GFS board 5371196-2/5455247
GE Logiq E9/vivid E9 GTX GA200726
GE Logiq E9 MRX Board 5393908/5393912
GE Logiq E9/vivid E9 GFI2 5161631
GE Logiq E9 BEP Power Supply 5393800-3/5166790-2
GE Voluson E6/Voluson E8 RSR KTI301394-2/KTI196357
GE Voluson E6/Voluson E8 RST KTI301148
GE Voluson E6/E8/E10 RSX KTZ303054 /KTI303054
GE Voluson E6/E8/E10 RFM201 FE mainboard KTZ303916
GE Voluson E6/E8/E10 RFM221 FE mainboard KTZ303915
GE Voluson E6/Voluson E8 RFI/ RFI21b Board KTI300614/KTI302197-6
GE Voluson S6/S8/P8 BF64 5396937-2
GE Voluson S6/S8/P8 BF128 5338209-2
GE Voluson S6/S8/P8 CPS Power supply 5393431
GE Voluson S6/S8/P8 RFS board 5364098-2/5364098-3
GE Voluson S6/S10/P8 BF192 board 5357234
Aloka Alpha 10 RX Beamformer board EP531800CE
Aloka Alpha 10 wave generator Board EP495000HH/EP495000HJ/EP495000FF
Aloka Alpha 10 High-voltage Board EP541800
Aloka Alpha 10 CPU mainboard EP496000
Hitachi F31 RX Beamformer board EP568900
Hitachi F31 mainboard EP575700BC/EP560800
Hitachi F37 TX/RS EP557400/EP557300
Hitachi F37 mainboard EP575700BC/EP560800
Hitachi F37 BF Beamformer board EP557400
Hitachi F37 RX mainboard EP557500
Aloka F75 CONT-B EP556700BB
Aloka F75 USP board EP556600
Aloka F75 Cell Board EP558800
Hitachi HI VISION Avius RDBF board 7513907A/7513612
Hitachi HI VISION Avius CONT-B 7513734A
Hitachi HI VISION Avius/Preirus Cell board 7345930A
Hitachi HI VISION Preirus RX Board CZH4AA
Hitachi HI VISION Preirus TX Board 7513629A
Hitachi HI VISION Preirus CONT-B 7513640A/CZ84AJ
Hitachi Arietta 60 TX  
Hitachi Arietta 60 RX  
Hitachi Arietta 60 CELL EU-9160C
Hitachi Arietta 70 TX EP572300AA
Hitachi Arietta 70 RX EP572900/EP572200
Hitachi Arietta 70 CELL  
Hitachi Noblus CELL  
Hitachi Noblus CONT-B  
Hitachi Ascendus TX  
Hitachi Ascendus CELL 7352830A
Siemens X150/G40 BE 10131804
Siemens X300 BE 2.0/BE 3.0/BE 7.5 10131990
Siemens X700 BE 10136465
Siemens X700 RC 10136467
Siemens X700 TI 11014292
Siemens Antares BE 7472421
Siemens Antares CB 7288504
Siemens S1000/S2000 RM200 10038592
Siemens S1000/S2000 RM220 10853882/10439172
Siemens S2000 RM300 10852163
Siemens S2000 high version/S3000 RM301 10854749
Toshiba Aplio 300/400/500 mainboard PM30-38696
Toshiba Aplio 300/400/500 VI  
Toshiba Aplio 300/400/500 TX PM30-38691
Toshiba Aplio 500 RX ywm2056*a
Toshiba Xario 200 TX PM30-32732-1
Toshiba Xario 200 RX PM30-32733-1

 

 

Konwledge Point

 

The solution of dealing with ultrasonic image interference

 

1. Probe interference: replace the probe

2. Equipment interference: replace the power supply or internal boards

3. External interference:

(1) Workstation interference: it is recommended to add several magnetic rings to the video cable, if it is not work, replace the ATX power supply, or add a filter to the host power input.

(2) Power input interference: add several magnetic rings to the power line.

 

If the above methods do not work, just try the method of eliminating the equipotentiality

, adding a shielding cloth on the bed, and connect a wire to the ground strap of the machine.

 

Get in touch with us

Enter Your Message

You Might Be Into These