Samsung V5-9 Ultrasound Probe Repair Oil And Sealing Problem Oil Leakage

Product Details:
Brand Name: Samsung
Model Number: V5-9
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Neutral Package
Delivery Time: 1-5 work days
Payment Terms: T/T,Western Union
  • Detail Information
  • Product Description

Detail Information

Category: Repair Ultrasonic Probe Description: Probes Repair
Service: Repair Service For Probes Warranty: 60 Days After Fixed
Condition: Original Purpose: Diagnosis For Ultrasound
High Light:

Samsung V5-9 Ultrasound Probe Repair

,

Oil Leakage Ultrasound Probe Repair

Product Description

 

Samsung V5-9 Ultrasound Probe Repair Oil and Sealing Problem Oil leakage

 

Probe Troubleshooting Summary

 

1. Check whether multiple probes are the same phenomenon, sometimes it is necessary to plug again

2. Lens and crystal failure are sometimes similar, both are shadowing on the image

3. If there is a single probe problem, replace the socket to have a check.

4. The high frequency probe (small parts probe) is sensitive. If only this probe doesn’t work, may be caused by machine failure.

 

 

Samsung V5-9 Ultrasound Probe Repair Oil And Sealing Problem Oil Leakage 0

 

Samsung V5-9 Ultrasound Probe Repair Oil And Sealing Problem Oil Leakage 1

 


 

Basic Ultrasound Transducer Types
1 Linear Transducers
2 convex or curved array Transducers
3 Sector Transducers
4 Endocavity Transducers
5 Tee Transducers
6 3d/4d Transducers
7 Phased Array Transducers

 

 

 

Knowledge point

 

 

One may be facing several types of problems while using the ultrasound machine probes. They may be one or more of the following:

 

1. Poor quality image: Poor image may be due to

    *Cracked or air bubbles on lens

    *Connector issue

    *Crystal damage

    *Tears on the sheath

 

2. Physical damage or broken housing: Physical damage may be due improper handling, dropping of probe, poor storage etc.

 

3. Noise: Noise may be due to broken cable, damaged / broken pins in connector or electrical interference.

    *Breakage of probe connector pins may be caused by improper insertion or connection.

    *Damage to cable occurs due to cables being ridden by some wheels or closure of drawers without proper placement of the probe inside, etc.

 

4. No image: If there is image being received, it could be a result of probe cable – connector breakage, probe compatibility issue or software issue.