GE 4C-RS Ultrasound Probe Repair Crystal Replacement Imagine Problem

Product Details:
Brand Name: GE
Model Number: 4C-RS
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Neutral Package
Delivery Time: 1-5 work days
Payment Terms: T/T,Western Union
  • Detail Information
  • Product Description

Detail Information

Category: Medical Imaging Equipment Description: Probes Repair
Service: Repair Service For Probes Warranty: 60 Days After Fixed
Condition: Original Purpose: Diagnosis For Ultrasound
High Light:

GE 4C-RS Ultrasound Probe Repair

,

Crystal Ultrasound Probe Repair

Product Description

 

Repair GE 4C-RS Ultrasound Probe Repair Crystal Replacement Imagine Problem

 

 

Crystal damage -Weak, dead or damaged crystals

 

Very often cause of crystal damage in ultrasound probes is dropping of probe on the floor or hitting of probe with gel bottle or other object. Once a probe is dropped its piezoelectric crystals may stop sending or receiving signals, resulting in scans with weak or dead elements. This leads to black lines in an image, these lines are called dropouts. Weak elements cause the faint little lines that don’t obscure much. These are the first signs that the elements are getting progressively damaged and need to be replaced. Instead of faint lines if the lines are thick and pronounced, the elements are dead. If there are thick lines in the scanned image, important things can be missed out during diagnosis. You may be harming the patient due to misdiagnosis.

 

Solution

 

Repair/Replace the Crystal

 

 

GE 4C-RS Ultrasound Probe Repair Crystal Replacement Imagine Problem 0

 

GE 4C-RS Ultrasound Probe Repair Crystal Replacement Imagine Problem 1

 

 

Other hot GE models we can repair:

 

GE C1-5-D
GE C1-5-RS
GE 4C
GE 4C-RS
GE 4C-A
GE 4C-D
GE 4C-SC
GE E8C/E8C-RS
GE E8CS
GE RIC5-9-D
GE 3CRF-D
GE C1-6-D
GE RAB4-8-RS
GE RAB2-5-RS
GE 6S-RS
GE 12L-RS
GE 3SC-RS
GE L6-12-RS
GE 11L
GE 11L-D
GE 12L-RS
GE 8C
GE 3S
GE 3S-RS
 

 

 

 

Common ultrasonic Probe Damage(Convex, Linear, Sector, Endocavity probes)

 

Common ultrasonic probe damage Solutions
Lens damage, wear, holes, swelling, delamination Lens replacement
Strain relief damage, separation Strain replacement
Nosepiece and probe separation and cracks

Cosmetic repairs

Cable cuts Cable patches, possible cable replacement
Connector housing electrical damage Major and minor electrical repairs, pin module replacement

 

 

 
Probe Troubleshooting Summary
 
1.Check whether multiple probes are the same phenomenon, sometimes it is necessary to plug again
2.Lens and crystal failure are sometimes similar, both are shadowing on the image
3.If there is a single probe problem, replace the socket to have a check.