Send Message
Guangzhou Rongtao Medical Tech LTD.

Aloka Alpha 5 Laptop Ultrasound Machine Repair Industrial Ultrasonic Transducer

Product Details:
Brand Name: Hitachi Aloka
Model Number: Hitachi Aloka Alpha 5
Payment & Shipping Terms:
Price: Negotiable
Packaging Details: Neutral Package
Delivery Time: 2-4 work days
Payment Terms: T/T,Western Union
  • Detail Information
  • Product Description

Detail Information

Category: Equipment Used For Ultrasound Description: Health Diagnostic Machine
System: Hospital Patient Monitor Warranty: 60 Days After Fixed
Condition: Hitachi Aloka Alpha 5 High Frequency Linear Transducer Purpose: Industrial Ultrasonic Transducer
Highlight:

Laptop Ultrasound Machine Repair

,

Aloka Alpha 5 Ultrasound Machine Repair

Product Description

 

Hitachi Aloka Alpha 5 System Reports Error

 

 

ALOKA alpha 5 is equipped with advanced front-end technology, original data processing platform,high-capacity digital beam generator (12bit digital beam generator) and other technologies to ensure the high-quality image of all organs in the body.And as well as the varties probes in ALOKA, ALOKA alpha 5 can meet the needs of linical diagnosis and scientific research,At present, ALOKA alpha 5 is used in many hospitals in China. Now we will analyze one of the common faults encountered in the use of ALOKA &α5.

 

Faults phenomenon

 

 

When operating the CW(continuous doppler), the diagnostic instrument crashed with an error prompt, and the other functions were all normal.Error warning: the machine detects abnormal voltage, please restart the system.

The parts with high failure rate&available in stock of this machine:mainboard, CW, RX Beam Former, CPU mainboard, TX/RX.

 

 

 

Aloka Alpha 5 Laptop Ultrasound Machine Repair Industrial Ultrasonic Transducer 0

 

 

 

Failure analysis

 

(1)The CW function of the diagnostic instrument can only be used in cardiac, and it has no such function in other conditions, so the CW board may be damaged.
(2) in case the appearance of the fault, the working voltage of CW measured by the attached power box drops significantly, which may be caused by the attached power box.
(3) this fault may also be caused by CW signal and loss of communication function.
(4) the heart probe (phased array probe) is composed of PW and CW, and the heart probe may be damaged.
(5) the software system is damaged, resulting in the loss of CW function.



Troubleshooting

 

It’s not working after replacing the attached power box and related circuit boards,the dead phenomenon didn&’t appeared when the heart probe was replaced . The problem was e circuits of the machine appeared,the restart of the machine are required.

 

 

Ultrasound parts that we can repair:

 

 

Repair List of Featured Ultrasonic Board & Assy
Brand System Description Part Number
GE Logiq P5 CPU mainboard 5168431
GE Logiq P6 CPU mainboard  
GE Logiq E9/vivid E9 GFI2 5161631
GE Voluson E6/Voluson E8 RSR KTI301394-2/KTI196357
GE Voluson E6/Voluson E8 RFI/ RFI21b Board KTI300614/KTI302197-6
GE Voluson S6/S8/P8 BF64 5396937-2
GE Voluson S6/S8/P8 RFS board 5364098-2/5364098-3
GE Voluson S6/S10/P8 BF192 board 5357234
Aloka Alpha 5 mainboard EP493700DD
Aloka Alpha 6 RX Beam Former EP555501AA
Aloka Alpha 6 CW board EP555700
Aloka Alpha 6 CPU mainboard EP537000/EP563000
Aloka Alpha 6 TX/RX EP555300
Aloka Alpha 6/Alpha 7 DOM EP550000AA
Aloka Alpha 10 RX Beamformer board EP531800CE
Aloka Alpha 10 wave generator Board EP495000HH/EP495000HJ/EP495000FF
Hitachi F37 TX/RS EP557400/EP557300
Hitachi F37 mainboard EP575700BC/EP560800
Aloka F75 USP board EP556600
Aloka F75 Cell Board EP558800
Hitachi HI VISION Avius RDBF board 7513907A/7513612
Hitachi Arietta 60 CELL EU-9160C
Hitachi Arietta 70 TX EP572300AA
Hitachi Arietta 70 CELL  
Hitachi Noblus CELL  
Hitachi Noblus CONT-B  
Hitachi Ascendus CELL 7352830A
Siemens X150/G40 BE 10131804
Siemens X300 BE 2.0/BE 3.0/BE 7.5 10131990
Siemens X700 BE 10136465
Siemens X700 RC 10136467
Siemens X700 TI 11014292
Siemens Antares BE 7472421
Siemens Antares CB 7288504
Siemens S2000 RM300 10852163
Siemens S2000 high version/S3000 RM301 10854749
iU22/iE33 EMB excelsior motherboard 453561419431/453561382231/453561419431
iU22/iE33 UMB Unified Motherboard 453561254492/453561360251
HD15 ACB acquisition control board 453561197145/453561197144
HD15 AIM board 4.53561E+11
CX50 control panel 4.53562E+11
CX50 mainboard 453561368033/453561622163/453561495832
Affiniti 70 ACQ acquisition control board  
EPIQ 5/EPIQ 7 ACQ Acquisition Module board 453561734844/453561704246
Biosound Mylab Series CPU mainboard 9501361000
Toshiba Aplio 300/400/500 mainboard PM30-38696
Toshiba Aplio 500 RX ywm2056*a
Toshiba Xario 200 TX PM30-32732-1
Toshiba Xario 200 RX PM30-32733-1
Remarks
1.The repair cycle is within 3-5 days.
2.Warranty after fixed:60 days.
3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge.
4.Package price is available if repair 3 pcs or more at one time.
5.Extra discount for VIP partners.
6.You could have different part No.under same description.

Get in touch with us

Enter Your Message

You Might Be Into These