Send Message
Guangzhou Rongtao Medical Tech LTD.

Aloka ALPHA 5/ALPHA 10 Backplane Board EP491100AB Ultrasound Accessories

Product Details:
Brand Name: Aloka
Model Number: EP491100AB
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Neutral Package
Delivery Time: 2-4 work days
Payment Terms: T/T, Western Union
  • Detail Information
  • Product Description

Detail Information

Category: Medical Ultrasonography Description: Backplane Board
Service: Exchange/Sell/Repair Warranty: 60 Days
Time Require: 2-4 Days Condition: Original Hitachi
Application: Ultrasound Machine
Highlight:

EP491100AB Backplane Board

,

ALPHA 5/ALPHA 10 Backplane Board

,

EP491100AB Ultrasound Accessories

Product Description

 

Aloka ALPHA 5/ALPHA 10 Backplane Board EP491100AB

 

1.Part number:EP491100AB
2.Pre-owned original one ,in excellent condition
3.We provide 60 days warranty

 

 

Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range.

 

Aloka  ALPHA 5/ALPHA 10 Backplane Board EP491100AB Ultrasound Accessories 0

 

 

 

Other ultrasound parts related to Aloka that we can offer:

 

Brand Machine type Description
Aloka Alpha 5 Main board EP493700DD
Aloka Alpha 5 Main board EP481200DD /EP525200
Aloka Alpha 5 Contral board
Aloka Alpha 5 EP496700BB,EP496800BB
Aloka SSD-3500/Alpha 5 EP531900AA
Aloka Alpha 5 EP512600AC
Aloka Alpha 5 EP444300LR
Aloka Alpha 6 CPU board EP537000AB/EP5630
Aloka Alpha 6 Power supply EU6046
Aloka Alpha 6 Contral board L-KEY-105B
Aloka Alpha 6 Alpha 6 number keyboard
Aloka Alpha 6 Touch screen
Aloka Alpha 6 LCD
Aloka Alpha 6 RX Beam Former EP555501AA
Aloka Alpha 6 EP555300
Aloka Alpha 6 EP550000AA
Aloka Alpha 6 CW Board EP555700
Aloka Alpha 6 3D/4D Board EP556000
Aloka Alpha 6/Alpha 7 RXBF & TP Board EP555500
Aloka Alpha 7/Alpha 6 BEAM FORMER Board 554101BB
Aloka Alpha 7 RX Board EP539100BB
Aloka Alpha 7 DBF&TXRX CONTROL BOARD
Rx Beam Former EP539500
Aloka Alpha 7 Rx Beam Former EP539501
Aloka Alpha 7 Probe interface board EP539000
Aloka Alpha 7 TX BOARD EP548300BB
Aloka Alpha 7 Connector Assy EP540100
Aloka Alpha 7 contral Board EP545100CC

 

 

Knowledge Point

 

Aloka Alpha 5

 

1.Technical Features
Advanced front-end information acquisition technology:
Alpha 5 uses highly integrated digital front-end technology (HDDF) and the new α series probe, as well as PST pure beam emission technology. These technologies work together to provide excellent image quality.
PST pure beam emission technology eliminates unnecessary signal components by controlling the sound beam and only emits the signals required for imaging, thereby enhancing the sensitivity and resolution of fundamental and harmonic imaging.
Highly Integrated Digital Front-end (HDDF):
Thanks to Aloka's advanced microelectronics technology, Alpha 5 has developed a unique high-speed ultrasound signal processor that can collect and process weaker signals from tissues.
Alpha 5 can achieve better resolution and penetration in both high-frequency and harmonic states.
High-speed front-end data stream processing (HR-FSB):
Alpha 5 converts all received information into 12-bit digital signals, greatly improving dynamic range and sensitivity.
New α series probe:
Combined with the latest materials science and probe cutting technology, Alpha 5's probe enhances the sharpness of the sound beam and improves image quality.
Built-in intelligent information management system (iDMS):
Patient data and images can be easily managed, and multiple formats such as DICOM, JPEG, BMP or TIFF can be supported for storage and transmission.
Doctors can listen to Doppler sounds in B mode, or perform post-processing analysis on images after the patient leaves.
Fine tissue harmonic imaging technology:
Alpha 5's integrated pure beam emission technology reduces acoustic wave deformation and noise signals in harmonic imaging, and wide aperture emission improves the resolution of harmonic imaging.
The latest generation of contrast harmonics is suitable for real-time contrast imaging at low sound pressure. It uses Aloka's unique contrast technology to extract only the harmonic information generated by the contrast agent, and observe the contrast agent perfusion in real time for a long time.
Blood flow profile technology:
Through this technology, doctors can easily obtain the blood flow velocity at each point on the entire vascular profile, thereby accurately calculating the blood flow of the blood vessel. This technology can also be used to calculate cardiac output.
Tei index component:
It provides accurate, simple, easy and repeatable measurement analysis and reporting functions for random analysis of overall cardiac function changes in cardiac contraction and diastole.
2. Clinical Application
Alpha 5 has a wide range of clinical applications and can be used to diagnose a variety of diseases, such as tumors, cardiovascular diseases, gynecological diseases, etc. By observing and analyzing ultrasound images, doctors can determine the location, size, morphology and other characteristics of the lesion, providing a basis for formulating treatment plans. At the same time, it can also be used for real-time ultrasound image guidance during surgery, as well as monitoring and evaluation of changes in patients' conditions.

 

Aloka Alpha 10

 

1. Technical Features
Fully crystal-controlled technology
α10 uses revolutionary front-end processing technology. Its groundbreaking composite pulse wave generator can control the vibration and stop of the ultrasonic chip from beginning to end, realizing complete control of the vibration of the ultrasonic chip.
This technology has revolutionized the spatial resolution and contrast resolution of the image.
Accurate delay control
α10 has a high-precision time delay control function, which can effectively suppress sidelobe artifacts and greatly improve the signal-to-noise ratio.
Composite array probe
Combined with the latest materials science and probe cutting technology, α10 realizes stereo matrix focusing, further improving spatial resolution and contrast resolution.
2. Functional characteristics
Original data acquisition and storage
After the ultrasound information is transmitted from the probe to the system without loss, α10 can store the original data, including information such as velocity, scattering, phase and brightness, and provide a platform foundation for the expansion of various forward-looking analysis functions.
Network compatibility and data sharing
α10 complies with the DICOM3.0 standard, can realize network storage, printing and transmission, and realize information and data sharing with medical information collection systems and hospital information systems (HIS). Early detection technology for vascular lesions
α10 is equipped with E-TRACKING, a vascular echo tracking technology. Based on the original information analysis platform, this technology automatically collects the radio frequency signal generated by the vascular pulsation, tracks and records the movement trajectory of the front and rear walls of the blood vessels in real time, and automatically calculates the change in the inner diameter of the blood vessels, which is displayed in the form of a curve with an accuracy of up to 0.01mm.
Through this technology, the hardness of the blood vessels can be quantitatively analyzed before the organic changes in the blood vessel wall occur, thereby realizing the early detection of diseases such as arteriosclerosis.
All-round M mode and image freezing adjustment
α10 supports the readjustment of two-dimensional, color and Doppler gain after image freezing, as well as the correction of blood flow measurement, and the readjustment of the baseline, gain and velocity range of the Doppler spectrum.
At the same time, it also provides an all-round M mode, which supports re-measurement and gain readjustment after freezing the image.
3. Clinical application
Arteriosclerosis detection
α10 can detect arteriosclerosis by quantitatively analyzing the hardness of the blood vessels before the organic changes in the blood vessel wall occur.
Cerebral infarction screening
For outpatients before undergoing traumatic examinations such as CT and angiography, the screening effect of α10 is very effective.
Treatment effect evaluation
α10 can evaluate the effect of drug treatment and removal of risk factors.
Vascular age judgment and prevention
By judging vascular age through β value, α10 can help prevent the occurrence of arteriosclerosis and guide patients to improve their lifestyle, such as eating habits and physical exercise.
Cardiac surgery preoperative examination
Before cardiac surgery bypass surgery, coronary angiography, and stent implantation, α10 can check whether the patient has vascular malformations, anatomical variations, and arterial stenosis or occlusion.
In addition, α10 also has significant advantages in displaying the micro-blood flow perfusion of superficial organ tumors, renal parenchymal blood flow, and infection process, which can minimize color spillover and display micro-vessels and low-speed blood flow. At the same time, it can also be used to observe the blood supply after organ transplantation and limb replantation, as well as the diagnosis and differential diagnosis of peripheral vascular spasm diseases (such as Raynaud's disease).

 

Various Ultrasound Systems that we served

 

 

GE Ultrasound System
LOGIQ P5, LOGIQ P6, LOGIQ S7, LOGIQ S8, VOLUSON 730, VOLUSON 730 PRO, VOLUSON 730 EXPERT, VOLUSON S8, VOLUSON P8, VOLUSON S6, VOLUSON S20, VOLUSON P8, VOLUSON E10, VIVID E9, LOGIQ BOOK, LOGIQ 5, LOGIQ 7, LOGIQ 9, LOGIQ E9, LOGIQ F6, LOGIQ F8, VIVID I, VIVID Q, VOLUSON I, VOLUSON E, VIVID S5, VIVID 3, VIVID 7...

 

 

Ultrasound System
HD11, HD11XE, HD15, HD7, ENVISOR C, IU22, IE33, EPIQ 5, EPIQ 7, AFFINITI 50, AFFINITI 50G, AFFINITI 70, CX30, CX50, CLEARVUE 550, CLEARVUE 650, CLEARVUE 850...

 

 

Hitachi-Aloka Ultrasound System
F31, F37, SSD-3500, SSD-3500 SV, SSD-4000, SSD-5000, ALPHA 5, ALPHA 6, ALPHA 7, ALPHA 10, PROSOUND F75, HI VISION AVIUS, HI VISION PREIRUS, EUB-5500, EUB-6500, EUB-7500, EUB-8500, Arietta 60, Arietta 70, Ascendus...

 

Get in touch with us

Enter Your Message

You Might Be Into These