Detail Information |
|||
Condition: | GE Original | Type: | Equipment Used For Ultrasound |
---|---|---|---|
Warranty: | 60/90 Days | Description: | Equipment Used In Hospitals |
Packing: | 1pcs.bag | Item: | Health Diagnostic Machine |
Product Description
Parts of GE probes we can offer:
Brand | Model | Compatible System |
GE | 3.5C | Logiq 3/ Logiq 5/ Logiq 7/ Logiq 9/ Logiq A5/ Logiq P5/ Logiq S6/Vivid7 |
GE | 3C | Logiq 3/ Logiq 5 |
GE | 3Cb | Logic 200 Pro |
GE | 3CRF | Logiq S6 |
GE | 3CRF-D | Logiq S8/ Logiq E9 |
GE | 3SP | LOGIQ P |
GE | 3Sp-D | Voluson E6/Voluson E8 / Bt08 & Higher version |
GE | 3S | vivid & Logiq series |
GE | 3S-RS | Loqigbook/XP/ Vivid-I |
GE | 3S-SC | venue 40 |
GE | 3S-RC | Logiq C5/ Logiq C2/ Logiq C3 |
The main components of a typical ultrasound transducer |
|
1 |
Lens |
2 |
Strain Relief |
3 |
Cyrstal |
4 |
Cable |
5 |
Connector Housing |
FAQ
Q: Can I have the goods returned if it is not working good?
A: Yes, goods are permitted to be returned in same received condition within 7 days. Refund will be handled within 2-4 working days after final confirmation (Freight & bank fee excluded). Shipping fee for return should be borne by buyers. No returns after 3 days if ordered wrong.
Q: If faults occurred after warranty date, can I contact you?
A: Sure, feel free to contact even years later. We'll look into the faults and try to find out some solutions/suggestions for you reference.
Q: Can I have the goods returned if it is not working good?
A: Yes, goods are permitted to be returned in same received condition within 7 days. Refund will be handled within 2-4 working days after final confirmation (Freight & bank fee excluded). Shipping fee for return should be borne by buyers. No returns after 3 days if ordered wrong.
Q: Is there any guarantee for the goods?
A: Fully-tested and safe packing before shipping, less than 3% warranty return claims of previous orders.
Some tips to maintain your ultrasound machine
1. Read the User Manual for Guidelines. ...
2. Use the Machine Properly. ...
3. Clean the Machine Daily. ...
4. Give the Transducer Extra Attention. ...
5. Disinfection is Very Important. ...
6. Clean the Air Filters Regularly. ...
7. Take Precautions During Transport.
8. Get a regular maintenance plan
Common Probe failure
1. Lens: Acoustic lens damage or bulge
2. Cable: the cable is damaged and the shell is cracked
3. Image attenuation: aging attenuation
4. Shadow: dark vertical line
5. Not recognized: probe not recognized
6. Interference: probe interference