Send Message
Guangzhou Rongtao Medical Tech LTD.

Used Ge Logiq E9 Probes 2nd Hand Ge Ultrasound Probes

Product Details:
Brand Name: GE
Model Number: BE9C
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Neutral Package
Delivery Time: 1-3 work days
Payment Terms: T/T, Western Union
  • Detail Information
  • Product Description

Detail Information

Category: Hospital Equipment Applications: OB/GYN
Warranty: 60 Days/ 90 Days Service: Outright Sale
Items: Hospital Machines Condition: Original GE
High Light:

Used Ge Logiq E9 Probes

,

2nd Hand Ge Ultrasound Probes

,

2nd Hand Ge Logiq E9 Probes

Product Description

 

Used Ultrasound Probe GE BE9C Bi-Plane/Urology/Logiq Series/Original


1. Type:bi-plane
2. Frequency: 3.5-11.0 Mhz
3. Compatible system: Logiq series
4. Application: urology
5. Condition: original, in good working condition
6. With 60 days warranty

 

 

Used Ge Logiq E9 Probes 2nd Hand Ge Ultrasound Probes 0

 

Used Ge Logiq E9 Probes 2nd Hand Ge Ultrasound Probes 1

 

 

 

Parts of GE probes we can offer:

 

Brand Model Compatible System
GE 3.5C Logiq 3/ Logiq 5/ Logiq 7/ Logiq 9/ Logiq A5/ Logiq P5/ Logiq S6/Vivid7
GE 3C Logiq 3/ Logiq 5
GE 3Cb Logic 200 Pro
GE 3CRF Logiq S6
GE 3CRF-D Logiq S8/ Logiq E9
GE 3SP LOGIQ P
GE 3Sp-D Voluson E6/Voluson E8 / Bt08 & Higher version
GE 3S vivid & Logiq series
GE 3S-RS Loqigbook/XP/ Vivid-I
GE 3S-SC venue 40
GE 3S-RC Logiq C5/ Logiq C2/ Logiq C3
GE 3SC-RS Vivid S5/ Vivid iq/ Vivid i
GE 3.8CA Logiq P3
GE 3V-D Vivid E9
GE 3.8C-RC Loqig C2/Logiq C3/ Logiq C5/ Logiq premiums
GE 4C Logiq & Vivid Series
GE 4C-RC Logiq C2/Logiq C3/Logiq C5/Logiq Premium
GE 4C-RS Vivid i Square/ Logiq e/ Vivid e
GE 4C-SC Venue 40
GE 4C-A Voluson 730
GE 4C-D Voluson E6/ E8 and Vivid E9
GE 4D3C-L Logiq 9/ Logiq A5/ Logiq P5/ Logiq S6
GE 4V-D Vivid E9
GE 4S Logiq and Vivid series
GE 5S pediatric cardiac
GE 5S-RS Vivid q/ Vivid i/Vivid S5/Vivid S6
GE 6.5C-RC Vivid q/ Vivid i
GE 7L Logiq and Vivid series
GE 7L-RC Logiq C2/ C5/ Logiq Premium
GE 739L Logiq 500 Pro/Vivid 3/Logiq 400 MD/Logiq 500 MD
GE 7S Logiq9/ Logiq 7/ Logiq S6/ Logiq 5/ Logiq 3 /Vivid 7/Vivid 3
GE 7.5L-RC Logiq C2/Logiq C3/Logiq C5/Logiq Premium
GE 8C Logiq & Vivid series
GE 8C-RS Voluson i/ Voluson e/ Logiq i/ Logiqbook XP/ Logiqbook/ Vivid i (from rev. 6.1.0)/ Vivid S5
GE 8L-RS Logiq e/ Vivid e/ Vivid i and Logiq Book XP
GE 9L Vivid 7 Pro/Vivid 3/Logiq 9/ Logiq 7/Logiq 5/Logiq 3/ Logiq 400
GE 9L-D Voluson E6/Voluson E8/Vivid E9
GE 9L-RS logiq e/ vivid e/ vivid I/ vivid q/ vivid s5/ vivid s6
GE 10Lb-RS Logiq book
GE 10S-RS Logiq Book/ Logiq e/ Vivid e/ Vivid i/ Logiq i/ Vivid i Square
GE 10L Logiq 3/5/7/9/ Vivid 3/4/A5/P5/7 Expert/7 Pro/ Logiq S6
GE 11L Logiq P5/A5/A5Pro/ Logiq P6/P6 Pro
GE 11L-D premium GE ultrasound machines
GE 12L Logiq & Vivid series
GE 12L-RS Logiq e/ Logiq l/ Vivid e/Vivid I Voluson e/Voluson I/Vivid Q/Vivid S5/ Vivid S6
GE 12L-SC Venue 40
GE 12S-D Vivid E9
GE AB2-7 Voluson S6/ Voluson S8/Voluson 730
GE AC2-5 Voluson 730
GE BE9C Logiq series

 

 

 

 

Storage for Transport of ultrasonic transducer

 

1. Make sure that the transducer is clean and disinfected before placing it in the case to avoid contaminating the foam that lines the carrying case.

2. Place the transducer in the case carefully to prevent kinking of the cable.

3. Before closing the lid, make sure no part of the transducer is protruding from the case.

4. Wrap the case in plastic material containing sealed-air pockets (such as Bubble Wrap material), and pack the wrapped case in a cardboard carton.

 

 

 

Common Probe failure

 

1. Lens: Acoustic lens damage or bulge

2. Cable: the cable is damaged and the shell is cracked

3. Image attenuation: aging attenuation

4. Shadow: dark vertical line

5. Not recognized: probe not recognized

6. Interference: probe interference

 

 

Probe Troubleshooting Summary

 

1. Check whether multiple probes are the same phenomenon, sometimes it is necessary to plug again

2. Lens and crystal failure are sometimes similar, both are shadowing on the image

3. If there is a single probe problem, replace the socket to have a check.

4. The high frequency probe (small parts probe) is sensitive. If only this probe doesn’t work, may be caused by machine failure.

Get in touch with us