Detail Information |
|||
Category: | Diagnostic Medical Device | Description: | Ultrasound System |
---|---|---|---|
Service: | Outright, Repair Service | Warranty: | 60 Days |
Condition: | Original | Purpose: | Hospital Use Equipment |
Highlight: | Prosound 6 Medical Ultrasound System,Hitachi Medical Ultrasound System,Hitachi aloka prosound 6 |
Product Description
Hitachi Aloka Prosound 6 Ultrasound System
1. Condition: Original,in good working condition
2. With 30 days warranty and 5-7 days lead time
3. Transducers: UST-9123,UST-5413,UST-987-7.5
The equiped probes requires specific consultation.
The machine can be start normally,equipped with general options and provide working warranty.
More models for Hitachi Aloka: Prosound 4,EUB-5500,EUB-7000,EUB-8500
Other Ultrasound Machine Maintenance we can offer:
Repair List of Featured Ultrasonic Board & Assy | |||
Brand | System | Description | Part Number |
GE | Logiq P5 | APS Power Supply | 5140505/5166108/5329667 |
GE | Logiq P5 | CPU mainboard | 5168431 |
GE | Logiq P5 | SYSCONPM | 5177848-3 |
GE | Logiq P6 | CPU mainboard | |
GE | Logiq P6 | PST Power Supply | 5245004/5244555 |
GE | Logiq P6 | SYSCONML | 5252326-3 |
GE | Logiq S7/Logiq S8 | CPS Power supply | 6626600 R02/5413249-3 |
GE | Logiq S7 | BF128 transmitting board | 5392446 |
GE | Logiq S7 | GFS board | 5371196 |
GE | Logiq S8 | BF192 Beamformer | 5357234-2 |
GE | Logiq S8 | GFS board | 5371196-2/5455247 |
GE | Logiq E9/vivid E9 | GTX | GA200726 |
GE | Logiq E9 | MRX Board | 5393908/5393912 |
GE | Logiq E9/vivid E9 | GFI2 | 5161631 |
GE | Logiq E9 | BEP Power Supply | 5393800-3/5166790-2 |
GE | Voluson E6/Voluson E8 | RSR | KTI301394-2/KTI196357 |
GE | Voluson E6/Voluson E8 | RST | KTI301148 |
GE | Voluson E6/E8/E10 | RSX | KTZ303054 /KTI303054 |
GE | Voluson E6/E8/E10 | RFM201 FE mainboard | KTZ303916 |
GE | Voluson E6/E8/E10 | RFM221 FE mainboard | KTZ303915 |
GE | Voluson E6/Voluson E8 | RFI/ RFI21b Board | KTI300614/KTI302197-6 |
GE | Voluson S6/S8/P8 | BF64 | 5396937-2 |
GE | Voluson S6/S8/P8 | BF128 | 5338209-2 |
GE | Voluson S6/S8/P8 | CPS Power supply | 5393431 |
GE | Voluson S6/S8/P8 | RFS board | 5364098-2/5364098-3 |
GE | Voluson S6/S10/P8 | BF192 board | 5357234 |
Aloka | Alpha 5 | mainboard | EP493700DD |
Aloka | Alpha 6 | RX Beam Former | EP555501AA |
Aloka | Alpha 6 | CW board | EP555700 |
Aloka | Alpha 6 | CPU mainboard | EP537000/EP563000 |
Aloka | Alpha 6 | TX/RX | EP555300 |
Aloka | Alpha 6/Alpha 7 | DOM | EP550000AA |
Aloka | Alpha 7 | RX Beam Former | EP539100BB/EP539500DG/EP539501DG |
Aloka | Alpha 7 | CPU mainboard | EP558900 |
Aloka | Alpha 7 | TI Board | EP539000 |
Aloka | Alpha 7 | TX board | EP548300BB |
Aloka | Alpha 7 | touch screen | L-Key-93H |
Aloka | Alpha 10 | RX Beamformer board | EP531800CE |
Aloka | Alpha 10 | wave generator Board | EP495000HH/EP495000HJ/EP495000FF |
Aloka | Alpha 10 | High-voltage Board | EP541800 |
Aloka | Alpha 10 | CPU mainboard | EP496000 |
Hitachi | F31 | RX Beamformer board | EP568900 |
Hitachi | F31 | mainboard | EP575700BC/EP560800 |
Hitachi | F37 | TX/RS | EP557400/EP557300 |
Hitachi | F37 | mainboard | EP575700BC/EP560800 |
Hitachi | F37 | BF Beamformer board | EP557400 |
Hitachi | F37 | RX mainboard | EP557500 |
Aloka | F75 | CONT-B | EP556700BB |
Aloka | F75 | USP board | EP556600 |
Aloka | F75 | Cell Board | EP558800 |
Hitachi | HI VISION Avius | RDBF board | 7513907A/7513612 |
Hitachi | HI VISION Avius | CONT-B | 7513734A |
Hitachi | HI VISION Avius/Preirus | Cell board | 7345930A |
Hitachi | HI VISION Preirus | RX Board | CZH4AA |
Hitachi | HI VISION Preirus | TX Board | 7513629A |
Hitachi | HI VISION Preirus | CONT-B | 7513640A/CZ84AJ |
Hitachi | Arietta 60 | TX | |
Hitachi | Arietta 60 | RX | |
Hitachi | Arietta 60 | CELL | EU-9160C |
Hitachi | Arietta 70 | TX | EP572300AA |
Hitachi | Arietta 70 | RX | EP572900/EP572200 |
Hitachi | Arietta 70 | CELL | |
Hitachi | Noblus | CELL | |
Hitachi | Noblus | CONT-B | |
Hitachi | Ascendus | TX | |
Hitachi | Ascendus | CELL | 7352830A |
Siemens | X150/G40 | BE | 10131804 |
Siemens | X300 | BE 2.0/BE 3.0/BE 7.5 | 10131990 |
Siemens | X700 | BE | 10136465 |
Siemens | X700 | RC | 10136467 |
Siemens | X700 | TI | 11014292 |
Siemens | Antares | BE | 7472421 |
Siemens | Antares | CB | 7288504 |
Siemens | S1000/S2000 | RM200 | 10038592 |
Siemens | S1000/S2000 | RM220 | 10853882/10439172 |
Siemens | S2000 | RM300 | 10852163 |
Siemens | S2000 high version/S3000 | RM301 | 10854749 |
iU22/iE33 | CB Channel Board | 453561156011/453561156012/453561303902 | |
iU22/iE33 | AIM Board | 453561210241/453561210243/453561210321/453561210243 | |
iU22/iE33 | FEC Front End Controller | 453561278261/453561278266/453561464291/453561153751 | |
iU22/iE33 | EMB excelsior motherboard | 453561419431/453561382231/453561419431 | |
iU22/iE33 | UMB Unified Motherboard | 453561254492/453561360251 | |
HD7/Envisor | T/R board | 453561448371 | |
HD11/HD11XE | SP Board | 453561210154/453561343282 | |
HD15 | ACB acquisition control board | 453561197145/453561197144 | |
HD15 | AIM board | 453561197306 | |
CX50 | control panel | 453561685791 | |
CX50 | mainboard | 453561368033/453561622163/453561495832 | |
CX50 | Power Supply board | 453561375144/453561384831/453561473243 | |
Affiniti 50 | ACQ acquisition control board | 4535161610416/4535161610426 | |
Affiniti 70 | ACQ acquisition control board | ||
EPIQ 5/EPIQ 7 | ACQ Acquisition Module board | 453561734844/453561704246 | |
Biosound | Mylab Series | CPU mainboard | 9501361000 |
Toshiba | Aplio 300/400/500 | mainboard | PM30-38696 |
Toshiba | Aplio 300/400/500 | VI | |
Toshiba | Aplio 300/400/500 | TX | PM30-38691 |
Toshiba | Aplio 500 | RX | ywm2056*a |
Toshiba | Xario 200 | TX | PM30-32732-1 |
Toshiba | Xario 200 | RX | PM30-32733-1 |
Remarks | |||
1.The repair cycle is within 3-5 days. | |||
2.Warranty after fixed:60 days. | |||
3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge. | |||
4.Package price is available if repair 3 pcs or more at one time. | |||
5.Extra discount for VIP partners. | |||
6.You could have different part No.under same description. |
Ultrasound repair
We have full confidence in our advanced repair techniques, which enable us to successfully repair more brands and models of ultrasonic probes in the industry. As a professional ultrasonic repair service provider in China, provide replacement parts that have passed testing and verification to help you avoid costly OEM.