Detail Information |
|||
Category: | Diagnostic Medical System | Description: | Ultrasound System |
---|---|---|---|
Service: | Repair Service For Ultrasound | Warranty: | 60 Days After Fixed |
Purpose: | Diagnosis Equiment For Hospital | Experience: | More Than 10 Years |
High Light: | GE VIVID Ultrasound Machine Repair,System Maintain Ultrasound Machine Repair |
Product Description
Ultrasound parts that we can repair:
Repair List of Featured Ultrasonic Board & Assy | |||
Brand | System | Description | Part Number |
GE | Logiq P5 | CPU mainboard | 5168431 |
GE | Logiq P6 | CPU mainboard | |
GE | Logiq E9/vivid E9 | GFI2 | 5161631 |
GE | Voluson E6/Voluson E8 | RSR | KTI301394-2/KTI196357 |
GE | Voluson E6/Voluson E8 | RFI/ RFI21b Board | KTI300614/KTI302197-6 |
GE | Voluson S6/S8/P8 | BF64 | 5396937-2 |
GE | Voluson S6/S8/P8 | RFS board | 5364098-2/5364098-3 |
GE | Voluson S6/S10/P8 | BF192 board | 5357234 |
Aloka | Alpha 5 | mainboard | EP493700DD |
Aloka | Alpha 6 | RX Beam Former | EP555501AA |
Aloka | Alpha 6 | CW board | EP555700 |
Aloka | Alpha 6 | CPU mainboard | EP537000/EP563000 |
Aloka | Alpha 6 | TX/RX | EP555300 |
Aloka | Alpha 6/Alpha 7 | DOM | EP550000AA |
Aloka | Alpha 10 | RX Beamformer board | EP531800CE |
Aloka | Alpha 10 | wave generator Board | EP495000HH/EP495000HJ/EP495000FF |
Hitachi | F37 | TX/RS | EP557400/EP557300 |
Hitachi | F37 | mainboard | EP575700BC/EP560800 |
Aloka | F75 | USP board | EP556600 |
Aloka | F75 | Cell Board | EP558800 |
Hitachi | HI VISION Avius | RDBF board | 7513907A/7513612 |
Hitachi | Arietta 60 | CELL | EU-9160C |
Hitachi | Arietta 70 | TX | EP572300AA |
Hitachi | Arietta 70 | CELL | |
Hitachi | Noblus | CELL | |
Hitachi | Noblus | CONT-B | |
Hitachi | Ascendus | CELL | 7352830A |
Siemens | X150/G40 | BE | 10131804 |
Siemens | X300 | BE 2.0/BE 3.0/BE 7.5 | 10131990 |
Siemens | X700 | BE | 10136465 |
Siemens | X700 | RC | 10136467 |
Siemens | X700 | TI | 11014292 |
Siemens | Antares | BE | 7472421 |
Siemens | Antares | CB | 7288504 |
Siemens | S2000 | RM300 | 10852163 |
Siemens | S2000 high version/S3000 | RM301 | 10854749 |
iU22/iE33 | EMB excelsior motherboard | 453561419431/453561382231/453561419431 | |
iU22/iE33 | UMB Unified Motherboard | 453561254492/453561360251 | |
HD15 | ACB acquisition control board | 453561197145/453561197144 | |
HD15 | AIM board | 4.53561E+11 | |
CX50 | control panel | 4.53562E+11 | |
CX50 | mainboard | 453561368033/453561622163/453561495832 | |
Affiniti 70 | ACQ acquisition control board | ||
EPIQ 5/EPIQ 7 | ACQ Acquisition Module board | 453561734844/453561704246 | |
Biosound | Mylab Series | CPU mainboard | 9501361000 |
Toshiba | Aplio 300/400/500 | mainboard | PM30-38696 |
Toshiba | Aplio 500 | RX | ywm2056*a |
Toshiba | Xario 200 | TX | PM30-32732-1 |
Toshiba | Xario 200 | RX | PM30-32733-1 |
Remarks | |||
1.The repair cycle is within 3-5 days. | |||
2.Warranty after fixed:60 days. | |||
3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge. | |||
4.Package price is available if repair 3 pcs or more at one time. | |||
5.Extra discount for VIP partners. | |||
6.You could have different part No.under same description. |
General process of reloading system software
1. Record version information and OPTION
2. Users operation and set BACKUP
3. Find the software CD and replace it with a new hard disk
4. Reboot your system, modify your BIOS to make CD-ROM boot first
5. Install basic software
6. After the basic software is installed, restart and install the application software
7. Restore user settings
About Us
Rongtao Medical, one of the leading service companies in China, has sold over 10,000+ probes, 20,000+ medical parts and repaired 5,000+ machines in the worldwide from 2014. As a comprehensive medical device company, we provide a wide range of diagnostic ultrasound services and other associated items (endoscopy, patient Monitor and ventilator).
Following are the main projects we based on:
Repair Ultrasound (Ultrasonic board/ASSY repair, Ultrasound probe repair)
Repair Associated Items (Endoscopy repair, Patient monitor repair, Ventilator repair)
Parts & Accessories (Original/compatible clone ultrasound transducer, Ultrasound board/part, Ultrasonic biopsy needle guide, Patient monitor module)
How we support?
★ Professional & passionate pre-sale service team
★ 10 years experienced repair technician team
★ Reliable & responsible quality control team
★ Experienced & specialize after-sale technical support team
We are committed to using our expertise in the industry to identify and provide the right medical equipment to our customers at the best price in a timely and professional manner.
Our Vision -- To be the top preferred third-party service company worldwide!
Enter Your Message